erhaps one of the most overlooked maintenance procedures is flushing the water heater and replacing the anode rod. Inspecting the anode rod seems like an out-of-sight, out-of-mind proposition — except for those who have to pull it to drain the tank for winterizing. Flushing the sediment that builds up in the bottom of the tank on regular basis — regardless of whether you have an Atwood or Suburban water heater — may not be quite as important as servicing the anode rod (Suburban models), but over time it’s possible to lose significant capacity, much less damage the tank.
Atwood tanks and the drain-plug threads are made of aluminum and using an aftermarket anode rod is not recommended. Don’t get fooled by those who tout their use; they can literally weld themselves into the drain hole from the electrolysis between the steel and the aluminum. Suburban water heaters have a porcelain-coated steel tank, which requires the use of an anode rod to protect against deterioration of the steel. The rule of thumb is to replace the anode when it’s about 50% deteriorated or annually, whichever occurs first.
Anode rods come in either aluminum or magnesium; they’re both designed to protect the steel tank. The difference between the two is the hardness of the material: Magnesium is softer, will deteriorate quicker and is far more effective than the aluminum counterpart (which will work if you have fairly soft water). There’s no question that the better protection afforded by using a magnesium anode rod (and its higher expense) is more cost-effective than purchasing an entire water heater. I recommend checking the anode rod at least every six months and replacing as necessary.
Anode rods also come in different lengths, with the longer ones suitable for 10- and 12-gallon water heaters. Magnesium anode rods have a tendency to make the water smell a little bit like sulfur; sanitizing the system with a bleach/water mixture will help solve the problem.
Make sure the gas and electric switches are off; you don’t want the water heater to come on when the water is drained; if the electric element is left on when the water is draining, it will burn up. The water in the tank must be cool before attempting to remove the anode rod (or pressure-relief valve). You will need a deep 11/16-inch socket with a short extension and a 1/2-inch breaker bar or ratchet for this job. The heat and corrosion can make the anode rod very difficult to remove. If you decide to replace the pressure relief valve, you will need a large pair of slip-lock pliers or a crescent wrench to remove it from the tank. You will also need a ¼-inch nut driver to remove the vent assembly to gain access to the pressure relief valve and high temperature Teflon tape to seal the threads.
Apply the Teflon tape to the anode rod threads and install it into the drain. The length of the anode rod makes it somewhat awkward, so be careful not to cross-thread when installing. Tighten the anode rod with the socket; these are very large threads, making it difficult to strip. At this point if you decide to change the pressure-relief valve, use the Teflon tape for the installation. You can torque this tightly as well and make sure the opening is pointing down.
If you did not change the pressure-relief valve and it leaks, you will need to turn the water off, cool down the water, relieve the pressure and change the valve. Repeat the process above to purge the air from the tank.
Both of these water heater brands are designed to have a small air gap at the top of the tank. Double check your work in a couple of days to make sure there are no drips.